Link Fault Pass-Through supported
Models available that are guaranteed to work in an extreme temperature environment (-40 to 75°C)
Relay output warning for power failure and port break alarm
Redundant daul 24 VDC power inputs
Designed for reliable and stable operation in harsh industrial environments
Introduction
MOXA Industrial Media Converter IMC-101, which is specially designed for reliable and stable operation in harsh industrial environments, provides industrial grade media conversion between 10/100BaseT(X) and 100BaseFX. Its reliable industrial design is excellent for keeping your industrial automation applications running continuously, and comes with a relay ouput warning alarm to help prevent damage and loss.
IMC-101 has been designed for use in harsh industrial environments, such as in hazardous locations (class 1 division 2 or zone 2), and complies with FCC, TÜV, UL, and CE standards. The IMC-101 Series is available in models that support an operating temperature of 0 to 60°C, and an extended operating temperature of -40 to 75°C. In addition, IMC-101 products are subjected to a 100% burn-in test, guaranteeing that they can be used in industrial automation control environments.
Link Fault Pass-Through
IMC-101's "Link Fault Pass-Through" feature overcomes a problem encountered when using traditional media converters. The problem is this. When one side of the link fails, the other side continues transmitting packets, and then waits for a response that never arrives from the disconnected side. What IMC-101 does is force the link to shut down as soon as it notices that the other link has failed, giving the application software a chance to react to the situation.
Redundant Power Inputs
IMC-101 provides two power inputs that can be connected simultaneously to live DC power sources. If one power input fails, the other source acts as a backup, and automatically satisfies IMC-101's power needs.
Relay Output Alarm by Port Break, Power Failure
IMC-101 provides relay contact outputs to warn technicians on the shop floor when the power fails or a port link is disconnected, so they can respond quickly with appropriate emergency operation procedures.
Features
Supports Link Fault Pass-Through
Supports 10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
Multi-mode and single-mode, with SC or ST connectors available
Power failure, port break alarm by relay output
Standard operating temperature (0 to 60°C) and extended operating temperature (-40 to 75°C) models available
For hazardous location (Class 1 Div. 2/Zone 2)
Long haul transmit distance of 40 km or 80 km |